NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
103 passende Meldungen · Seite 2 von 4Index aktualisiert vor 2 Minuten · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
mittel5.4 CVE-2023-5769 A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. hitachienergy · rtu520_firmware, hitachienergy · rtu530_firmware, hitachienergy · rtu540_firmware +1 2023-12-14 mittel5.9 CVE-2023-5768 A vulnerability exists in the HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. hitachienergy · rtu520_firmware, hitachienergy · rtu530_firmware, hitachienergy · rtu540_firmware +1 2023-12-04 mittel6.0 CVE-2023-5767 A vulnerability exists in the webserver that affects the RTU500 series product versions listed below. hitachienergy · rtu520_firmware, hitachienergy · rtu530_firmware, hitachienergy · rtu540_firmware +1 2023-12-04 mittel6.5 CVE-2023-4518 A vulnerability exists in the input validation of the GOOSE messages where out of range values received and processed by the IED caused a reboot of the device. hitachienergy · relion_670_firmware, hitachienergy · relion_650_firmware, hitachienergy · relion_sam600-io_firmware 2023-12-01 mittel5.3 CVE-2023-5516 Poorly constructed webap requests and URI components with special characters trigger unhandled errors and exceptions, disclosing information about the underlyi… hitachienergy · esoms 2023-11-01 mittel5.3 CVE-2023-5515 The responses for web queries with certain parameters disclose internal path of resources. hitachienergy · esoms 2023-11-01 mittel5.3 CVE-2023-5514 The response messages received from the eSOMS report generation using certain parameter queries with full file path can be abused for enumerating the local fil… hitachienergy · esoms 2023-11-01 niedrig2.7 CVE-2023-2622 Authenticated clients can read arbitrary files on the MAIN Computer system using the remote procedure call (RPC) of the InspectSetup service endpoint. hitachienergy · modular_advanced_control_for_hvdc 2023-11-01 mittel6.5 CVE-2023-2621 The McFeeder server (distributed as part of SSW package), is susceptible to an arbitrary file write vulnerability on the MAIN computer system. hitachienergy · modular_advanced_control_for_hvdc 2023-11-01 mittel6.9 CVE-2023-4816 A vulnerability exists in the Equipment Tag Out authentication, when configured with Single Sign-On (SSO) with password validation in T214. hitachienergy · asset_suite 2023-09-11 hoch7.5 CVE-2022-4608 A vulnerability exists in HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. hitachienergy · rtu500_firmware 2023-07-26 hoch7.5 CVE-2022-2502 A vulnerability exists in the HCI IEC 60870-5-104 function included in certain versions of the RTU500 series product. hitachienergy · rtu500_firmware 2023-07-26 mittel4.0 CVE-2023-1711 A vulnerability exists in a FOXMAN-UN and UNEM logging component, it only affects systems that use remote authentication to the network elements. hitachienergy · foxman-un, hitachienergy · unem 2023-05-30 hoch7.5 CVE-2022-3685 A vulnerability exists in the SDM600 software. hitachienergy · sdm600 2023-03-28 mittel4.8 CVE-2022-3686 A vulnerability exists in a SDM600 endpoint. hitachienergy · sdm600 2023-03-28 hoch7.5 CVE-2022-3684 A vulnerability exists in a SDM600 endpoint. hitachienergy · sdm600 2023-03-28 hoch7.7 CVE-2022-3683 A vulnerability exists in the SDM600 API web services authorization validation implementation. hitachienergy · sdm600 2023-03-28 kritisch9.9 CVE-2022-3682 A vulnerability exists in the SDM600 file permission validation. hitachienergy · sdm600 2023-03-28 mittel5.9 CVE-2022-3353 A vulnerability exists in the IEC 61850 communication stack that affects multiple Hitachi Energy products. hitachienergy · sys600_firmware, hitachienergy · rtu500_firmware, hitachienergy · reb500_firmware +9 2023-02-21 mittel5.7 CVE-2022-2155 A vulnerability exists in the affected versions of Lumada APM’s User Asset Group feature due to a flaw in access control mechanism implementation on the “Limit… hitachienergy · lumada_asset_performance_management 2023-01-12 hoch8.3 CVE-2022-3929 Communication between the client and the server application of the affected products is partially done using CORBA (Common Object Request Broker Architecture) … hitachienergy · foxman-un, hitachienergy · unem 2023-01-05 hoch7.1 CVE-2022-3928 Hardcoded credential is found in affected products' message queue. hitachienergy · foxman-un, hitachienergy · unem 2023-01-05 hoch8.0 CVE-2022-3927 The affected products store both public and private key that are used to sign and protect Custom Parameter Set (CPS) file from modification. hitachienergy · foxman-un, hitachienergy · unem 2023-01-05 hoch7.1 CVE-2021-40342 In the DES implementation, the affected product versions use a default key for encryption. hitachienergy · foxman-un, hitachienergy · unem 2023-01-05 hoch7.1 CVE-2021-40341 DES cipher, which has inadequate encryption strength, is used Hitachi Energy FOXMAN-UN to encrypt user credentials used to access the Network Elements. hitachienergy · foxman-un, hitachienergy · unem 2023-01-05 hoch7.1 CVE-2022-2513 A vulnerability exists in the Intelligent Electronic Device (IED) Connectivity Package (ConnPack) credential storage function in Hitachi Energy’s PCM600 produc… hitachienergy · 650connectivitypackage, hitachienergy · 670connectivitypackage, hitachienergy · gms600connectivitypackage +3 2022-11-22 hoch8.8 CVE-2022-3388 An input validation vulnerability exists in the Monitor Pro interface of MicroSCADA Pro and MicroSCADA X SYS600. hitachienergy · microscada_pro_sys600, hitachienergy · microscada_x_sys600 2022-11-21 hoch7.5 CVE-2022-2277 Improper Input Validation vulnerability exists in the Hitachi Energy MicroSCADA X SYS600's ICCP stack during the ICCP communication establishment causes a deni… hitachienergy · microscada_x_sys600 2022-09-14 hoch7.5 CVE-2022-29922 Improper Input Validation vulnerability in the handling of a specially crafted IEC 61850 packet with a valid data item but with incorrect data type in the IEC … hitachienergy · microscada_x_sys600 2022-09-14 mittel5.3 CVE-2022-29492 Improper Input Validation vulnerability in the handling of a malformed IEC 104 TCP packet in the Hitachi Energy MicroSCADA X SYS600, MicroSCADA Pro SYS600. hitachienergy · microscada_x_sys600 2022-09-14

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.