NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
132 passende Meldungen · Seite 4 von 5Index aktualisiert vor 8 Minuten · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
mittel5.3 CVE-2018-14803 Philips e-Alert Unit (non-medical device), Version R2.1 and prior. philips · e-alert_firmware 2018-09-26 mittel6.2 CVE-2018-14801 In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, an attacker with both the superuser password and physical acce… philips · pagewriter_tc70_firmware, philips · pagewriter_tc50_firmware, philips · pagewriter_tc30_firmware +2 2018-08-22 niedrig3.7 CVE-2018-14799 In Philips PageWriter TC10, TC20, TC30, TC50, TC70 Cardiographs, all versions prior to May 2018, the PageWriter device does not sanitize data entered by user. philips · pagewriter_tc70_firmware, philips · pagewriter_tc50_firmware, philips · pagewriter_tc30_firmware +2 2018-08-22 mittel6.7 CVE-2018-14789 In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 3.1 or prior and Xcelera Version 4.1 or prior), an unquoted search path or element vulner… philips · intellispace_cardiovascular, philips · xcelera 2018-08-22 hoch7.8 CVE-2018-14787 In Philips' IntelliSpace Cardiovascular (ISCV) products (ISCV Version 2.x or prior and Xcelera Version 4.1 or prior), an attacker with escalated privileges cou… philips · intellispace_cardiovascular, philips · xcelera 2018-08-22 hoch7.8 CVE-2017-3210 Applications developed using the Portrait Display SDK, versions 2.30 through 2.34, default to insecure configurations which allow arbitrary code execution. portrait · portrait_display_sdk, fujitsu · displayview_click, fujitsu · displayview_click_suite +3 2018-07-24 hoch8.2 CVE-2018-10601 IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX10… philips · intellivue_mp2_firmware, philips · intellivue_x2_firmware, philips · intellivue_mp30_firmware +9 2018-06-05 mittel5.3 CVE-2018-10599 IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX10… philips · intellivue_mp2_firmware, philips · intellivue_x2_firmware, philips · intellivue_mp30_firmware +9 2018-06-05 hoch8.3 CVE-2018-10597 IntelliVue Patient Monitors MP Series (including MP2/X2/MP30/MP50/MP70/NP90/MX700/800) Rev B-M, IntelliVue Patient Monitors MX (MX400-550) Rev J-M and (X3/MX10… philips · intellivue_mp2_firmware, philips · intellivue_x2_firmware, philips · intellivue_mp30_firmware +9 2018-06-05 hoch8.7 CVE-2018-8861 Vulnerabilities within the Philips Brilliance CT kiosk environment (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance i… philips · brilliance_firmware_64, philips · brilliance_ict_sp_firmware, philips · brilliance_ict_firmware +1 2018-05-04 hoch7.8 CVE-2018-8857 Philips Brilliance CT software (Brilliance 64 version 2.6.2 and prior, Brilliance iCT versions 4.1.6 and prior, Brillance iCT SP versions 3.2.4 and prior, and … philips · brilliance_firmware_64, philips · brilliance_ict_sp_firmware, philips · brilliance_ict_firmware +1 2018-05-04 hoch8.8 CVE-2018-8853 Philips Brilliance CT devices operate user functions from within a contained kiosk in a Microsoft Windows operating system. philips · brilliance_firmware_64, philips · brilliance_ict_sp_firmware, philips · brilliance_ict_firmware +1 2018-05-04 mittel6.5 CVE-2017-9658 Certain 802.11 network management messages have been determined to invoke wireless access point blacklisting security defenses when not required, which can nec… philips · intellivue_mx40_firmware 2018-04-30 mittel6.5 CVE-2017-9657 Under specific 802.11 network conditions, a partial re-association of the Philips IntelliVue MX40 Version B.06.18 WLAN monitor to the central monitoring statio… philips · intellivue_mx40_firmware 2018-04-30 kritisch9.1 CVE-2017-9656 The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privi… philips · dosewise 2018-04-24 hoch8.8 CVE-2017-9654 The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. philips · dosewise 2018-04-24 kritisch9.8 CVE-2018-7498 In Philips Alice 6 System version R8.0.2 or prior, the lack of proper data encryption passes up the guarantees of confidentiality, integrity, and accountabilit… philips · alice_6_firmware 2018-03-28 kritisch9.8 CVE-2018-5451 In Philips Alice 6 System version R8.0.2 or prior, when an actor claims to have a given identity, the software does not prove or insufficiently proves that the… philips · alice_6_firmware 2018-03-28 kritisch9.8 CVE-2018-5474 Philips Intellispace Portal all versions 7.0.x and 8.0.x have an input validation vulnerability that could allow a remote attacker to execute arbitrary code or… philips · intellispace_portal 2018-03-26 kritisch9.8 CVE-2018-5472 Philips Intellispace Portal all versions 7.0.x and 8.0.x have an insecure windows permissions vulnerability that could allow an attacker to gain unauthorized a… philips · intellispace_portal 2018-03-26 hoch7.8 CVE-2018-5470 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an unquoted search path or element vulnerability that has been identified, which may allow an… philips · intellispace_portal 2018-03-26 kritisch9.8 CVE-2018-5468 Philips Intellispace Portal all versions 7.0.x and 8.0.x have a remote desktop access vulnerability that could allow an attacker to gain unauthorized access an… philips · intellispace_portal 2018-03-26 hoch7.5 CVE-2018-5466 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a self-signed SSL certificate vulnerability this could allow an attacker to gain unauthorized… philips · intellispace_portal 2018-03-26 hoch7.5 CVE-2018-5464 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an untrusted SSL certificate vulnerability this could allow an attacker to gain unauthorized … philips · intellispace_portal 2018-03-26 hoch7.5 CVE-2018-5462 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have an SSL incorrect hostname certificate vulnerability this could allow an attacker to gain unau… philips · intellispace_portal 2018-03-26 hoch7.5 CVE-2018-5458 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability using SSL legacy encryption that could allow an attacker to gain unauthorized… philips · intellispace_portal 2018-03-26 hoch8.1 CVE-2018-5454 Philips IntelliSpace Portal all versions of 8.0.x, and 7.0.x have a vulnerability where code debugging methods are enabled, which could allow an attacker to re… philips · intellispace_portal 2018-03-26 mittel6.3 CVE-2018-5438 Philips ISCV application prior to version 2.3.0 has an insufficient session expiration vulnerability where an attacker could reuse the session of a previously … philips · intellispace_cardiovascular 2018-03-20 hoch7.2 CVE-2017-14111 The workstation logging function in Philips IntelliSpace Cardiovascular (ISCV) 2.3.0 and earlier and Xcelera R4.1L1 and earlier records domain authentication c… philips · intellispace_cardiovascular, philips · xcelera 2017-11-17 hoch7.5 CVE-2017-14797 Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the… philips · hue_bridge_bsb002_firmware 2017-10-01

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.