NetSight
high7.8Public exploit code

CVE-2011-4878

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA port…

Public exploit code

Working exploit or proof of concept code has been published for this vulnerability. Treat unpatched systems as at risk.

Impact

Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.

Affected products

VendorProductAffected versions
SiemensWincc Flexible
Versions 2004, 2005, 2007, 2008
SiemensWincc
through v11
Version v11
SiemensSimatic Hmi Panels
Versions comfort_panels, mobile_panels, mp, op, tp
SiemensWincc Runtime Advanced
Version v11
SiemensWincc Flexible Runtime
All versions

Weakness classification

References