NetSight
critical9.8

CVE-2017-9852

An Incorrect Password Management issue was discovered in SMA Solar Technology products.

Impact

An Incorrect Password Management issue was discovered in SMA Solar Technology products. Default passwords exist that are rarely changed. User passwords will almost always be default. Installer passwords are expected to be default or similar across installations installed by the same company (but are sometimes changed). Hidden user accounts have (at least in some cases, though more research is required to test this for all hidden user accounts) a fixed password for all devices; it can never be changed by a user. Other vulnerabilities exist that allow an attacker to get the passwords of these hidden user accounts. NOTE: the vendor reports that it has no influence on the allocation of passwords, and that global hardcoded master passwords do not exist. Also, only Sunny Boy TLST-21 and TL-21 and Sunny Tripower TL-10 and TL-30 could potentially be affected

Affected products

VendorProductAffected versions
SmaSunny Boy 3600 Firmware
All versions
SmaSunny Boy 5000 Firmware
All versions
SmaSunny Tripower Core1 Firmware
All versions
SmaSunny Tripower 15000tl Firmware
All versions
SmaSunny Tripower 20000tl Firmware
All versions
SmaSunny Tripower 25000tl Firmware
All versions
SmaSunny Tripower 5000tl Firmware
All versions
SmaSunny Tripower 12000tl Firmware
All versions
SmaSunny Tripower 60 Firmware
All versions
SmaSunny Boy 3000tl Firmware
All versions
SmaSunny Boy 3600tl Firmware
All versions
SmaSunny Boy 4000tl Firmware
All versions

Weakness classification

References