An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0.

Impact

An issue was discovered on Zyxel GS1900 devices with firmware before 2.50(AAHH.0)C0. Due to lack of input validation in the cmd_sys_traceroute_exec(), cmd_sys_arp_clear(), and cmd_sys_ping_exec() functions in the libclicmd.so library contained in the firmware, an attacker could leverage these functions to call system() and execute arbitrary commands on the switches. (Note that these functions are currently not called in this version of the firmware, however an attacker could use other vulnerabilities to finally use these vulnerabilities to gain code execution.)

Affected products

VendorProductAffected versions
ZyxelGs1900-8 Firmware
before 2.50\(aahh.0\)c0
ZyxelGs1900-8hp Firmware
before 2.50\(aahi.0\)c0
ZyxelGs1900-10hp Firmware
before 2.50\(aazi.0\)c0
ZyxelGs1900-16 Firmware
before 2.50\(aahj.0\)c0
ZyxelGs1900-24e Firmware
before 2.50\(aahk.0\)c0
ZyxelGs1900-24 Firmware
before 2.50\(aahl.0\)c0
ZyxelGs1900-24hp Firmware
before 2.50\(aahm.0\)c0
ZyxelGs1900-48 Firmware
before 2.50\(aahn.0\)c0
ZyxelGs1900-48hp Firmware
before 2.50\(aaho.0\)c0

Weakness classification

References