NetSight
critical9.8

CVE-2020-10271

MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless …

Impact

MiR100, MiR200 and other MiR robots use the Robot Operating System (ROS) default packages exposing the computational graph to all network interfaces, wireless and wired. This is the result of a bad set up and can be mitigated by appropriately configuring ROS and/or applying custom patches as appropriate. Currently, the ROS computational graph can be accessed fully from the wired exposed ports. In combination with other flaws such as CVE-2020-10269, the computation graph can also be fetched and interacted from wireless networks. This allows a malicious operator to take control of the ROS logic and correspondingly, the complete robot given that MiR's operations are centered around the framework (ROS).

Affected products

VendorProductAffected versions
AliasroboticsMir100 Firmware
through 2.8.1.1
AliasroboticsMir200 Firmware
through 2.8.1.1
AliasroboticsMir250 Firmware
through 2.8.1.1
AliasroboticsMir500 Firmware
through 2.8.1.1
AliasroboticsMir1000 Firmware
through 2.8.1.1
Mobile-Industrial-RoboticsEr200 Firmware
through 2.8.1.1
Enabled-RoboticsEr-Lite Firmware
through 2.8.1.1
Enabled-RoboticsEr-Flex Firmware
through 2.8.1.1
Enabled-RoboticsEr-One Firmware
through 2.8.1.1
Uvd-RobotsUvd Robots Firmware
through 2.8.1.1

Weakness classification