NetSight
medium5.9

CVE-2020-28391

A vulnerability has been identified in SCALANCE X-200 switch family (incl.

Impact

A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.

Affected products

VendorProductAffected versions
SiemensScalance X200-4pirt Firmware
before 5.5.0
SiemensScalance X201-3pirt Firmware
before 5.5.0
SiemensScalance X202-2irt Firmware
before 5.5.0
SiemensScalance X202-2pirt Firmware
before 5.5.0
SiemensScalance X202-2pirt Siplus Net Firmware
before 5.5.0
SiemensScalance X204irt Firmware
before 5.5.0
SiemensScalance X307-3 Firmware
All versions
SiemensScalance X307-3ld Firmware
All versions
SiemensScalance X308-2 Firmware
All versions
SiemensScalance X308-2ld Firmware
All versions
SiemensScalance X308-2lh Firmware
All versions
SiemensScalance X308-2lh\+ Firmware
All versions

Weakness classification

References