CVE-2022-29875
A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A…
Impact
A vulnerability has been identified in Biograph Horizon PET/CT Systems (All VJ30 versions < VJ30C-UD01), MAGNETOM Family (NUMARIS X: VA12M, VA12S, VA10B, VA20A, VA30A, VA31A), MAMMOMAT Revelation (All VC20 versions < VC20D), NAEOTOM Alpha (All VA40 versions < VA40 SP2), SOMATOM X.cite (All versions < VA30 SP5 or VA40 SP2), SOMATOM X.creed (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.All (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Now (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Open Pro (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Sim (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Top (All versions < VA30 SP5 or VA40 SP2), SOMATOM go.Up (All versions < VA30 SP5 or VA40 SP2), Symbia E/S (All VB22 versions < VB22A-UD03), Symbia Evo (All VB22 versions < VB22A-UD03), Symbia Intevo (All VB22 versions < VB22A-UD03), Symbia T (All VB22 versions < VB22A-UD03), Symbia.net (All VB22 versions < VB22A-UD03), syngo.via VB10 (All versions), syngo.via VB20 (All versions), syngo.via VB30 (All versions), syngo.via VB40 (All versions < VB40B HF06), syngo.via VB50 (All versions), syngo.via VB60 (All versions < VB60B HF02). The application deserialises untrusted data without sufficient validations that could result in an arbitrary deserialization. This could allow an unauthenticated attacker to execute code in the affected system if ports 32912/tcp or 32914/tcp are reachable.
Affected products
| Vendor | Product | Affected versions |
|---|---|---|
| Siemens | Biograph Horizon Pet\/Ct Systems Firmware | from vj30 before vj30c-ud01 |
| Siemens | Magnetom Numaris X Firmware | Versions va10b, va12m, va12s, va20a, va30a, va31a |
| Siemens | Mammomat Revelation Firmware | from vc20 before vc20d |
| Siemens | Naeotom Alpha Firmware | Version va40 |
| Siemens | Somatom X.Cite Firmware | before va30 Versions va30, va40 |
| Siemens | Somatom X.Creed Firmware | before va30 Versions va30, va40 |
| Siemens | Somatom Go.All Firmware | before va30 Versions va30, va40 |
| Siemens | Somatom Go.Now Firmware | before va30 Versions va30, va40 |
| Siemens | Somatom Go.Open Pro Firmware | before va30 Versions va30, va40 |
| Siemens | Somatom Go.Sim Firmware | before va30 Versions va30, va40 |
| Siemens | Somatom Go.Up Firmware | before va30 Versions va30, va40 |
| Siemens | Symbia E Firmware | from vb22 before vb22a-ud03 |