NetSight
medium6.5

CVE-2024-53649

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6M…

Impact

A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver. This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices.

Affected products

ProductAffected versions
SIPROTEC 5 6MD84 (CP300) (All
before 9.80

Versions were read from the advisory text. No structured product data has been published for this record yet.

Weakness classification

References