NetSight
hoch8.8

CVE-2019-9013

An issue was discovered in 3S-Smart CODESYS V3 products.

Auswirkung

An issue was discovered in 3S-Smart CODESYS V3 products. The application may utilize non-TLS based encryption, which results in user credentials being insufficiently protected during transport. All variants of the following CODESYS V3 products in all versions containing the CmpUserMgr component are affected regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control RTE V3, CODESYS Control RTE V3 (for Beckhoff CX), CODESYS Control Win V3 (also part of the CODESYS Development System setup), CODESYS V3 Simulation Runtime (part of the CODESYS Development System), CODESYS Control V3 Runtime System Toolkit, CODESYS HMI V3.

Ein Angreifer kann die Lücke aus demselben lokalen Netzwerk ausnutzen, ohne Anmeldung, ohne Zutun eines Nutzers. Bei Erfolg: hohes Risiko, dass Daten ausgelesen werden, hohes Risiko, dass Daten oder Systeme verändert werden, hohes Risiko für Ausfälle.

Betroffene Produkte · Codesys

ProduktBetroffene Versionen
Control For Beaglebone Sl
ab 3.0 vor 3.5.16.0
control for empc-a\/imx6 sl
ab 3.0 vor 3.5.16.0
Control For Iot2000 Sl
ab 3.0 vor 3.5.16.0
Control For Linux Sl
ab 3.0 vor 3.5.16.0
Control For Pfc100 Sl
ab 3.0 vor 3.5.16.0
Control For Pfc200 Sl
ab 3.0 vor 3.5.16.0
Control Rte Sl
ab 3.0 vor 3.5.16.0
Control Win Sl
ab 3.0 vor 3.5.16.0
Development System
ab 3.0 vor 3.5.16.0
Hmi Sl
ab 3.0 vor 3.5.16.0
Raspberry Pi
ab 3.0 vor 3.5.16.0
Runtime Toolkit
ab 3.0 vor 3.5.16.0

Schwachstellenklasse