CVE-2020-15158
In libIEC61850 before version 1.4.3, when a message with COTP message length field with value < 4 is received an integer underflow will happen leading to heap …
Auswirkung
In libIEC61850 before version 1.4.3, when a message with COTP message length field with value < 4 is received an integer underflow will happen leading to heap buffer overflow. This can cause an application crash or on some platforms even the execution of remote code. If your application is used in open networks or there are untrusted nodes in the network it is highly recommend to apply the patch. This was patched with commit 033ab5b. Users of version 1.4.x should upgrade to version 1.4.3 when available. As a workaround changes of commit 033ab5b can be applied to older versions.
Ein Angreifer kann die Lücke über das Netzwerk ausnutzen, mit einem normalen Benutzerkonto, ohne Zutun eines Nutzers. Dafür müssen bestimmte Bedingungen erfüllt sein, was einen Angriff erschwert. Bei Erfolg: geringes Risiko, dass Daten ausgelesen werden, geringes Risiko, dass Daten oder Systeme verändert werden, hohes Risiko für Ausfälle. Der Angriff kann über die verwundbare Komponente hinaus wirken.
Betroffene Produkte · Mz-automation
| Produkt | Betroffene Versionen |
|---|---|
| Libiec61850 | ab 1.4.0 vor 1.4.3 |
Schwachstellenklasse
Referenzen
- NVD-Eintrag
- CVE.org-Eintrag
- https://github.com/mz-automation/libiec61850/commit/033ab5b6488250c8c3b838f25a7cbc3e099230bb
- https://github.com/mz-automation/libiec61850/issues/250
- https://github.com/mz-automation/libiec61850/security/advisories/GHSA-pq77-fmf7-hjw8
- https://github.com/mz-automation/libiec61850/commit/033ab5b6488250c8c3b838f25a7cbc3e099230bb
- https://github.com/mz-automation/libiec61850/issues/250
- https://github.com/mz-automation/libiec61850/security/advisories/GHSA-pq77-fmf7-hjw8