NetSight
niedrig2.3

CVE-2026-124760

P-Net before 1.0.4 sets the alarm receiver state to waiting for confirmation before the data of a received alarm notification is parsed.

Auswirkung

P-Net before 1.0.4 sets the alarm receiver state to waiting for confirmation before the data of a received alarm notification is parsed. If the parsing fails the state is not restored, and later alarm notifications of the same priority are discarded without acknowledge until the Application Relationship is released. The Application Relationship and the cyclic data exchange keep working. The attacker must be able to send an alarm notification in the context of an established Application Relationship and requires ADJACENT network access.

Ein Angreifer kann die Lücke aus demselben lokalen Netzwerk ausnutzen, ohne Anmeldung, ohne Zutun eines Nutzers. Dafür müssen bestimmte Bedingungen erfüllt sein, was einen Angriff erschwert. Bei Erfolg: geringes Risiko für Ausfälle.

Betroffene Produkte · RT-Labs

ProduktBetroffene Versionen
P-Net
vor 1.0.4

Schwachstellenklasse

Referenzen