NetSight
mittel6.5

CVE-2026-57032

An Improper Handling of Undefined Parameters vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on EX Series devices allows an au…

Auswirkung

An Improper Handling of Undefined Parameters vulnerability in the packet forwarding engine (pfe) of Juniper Networks Junos OS on EX Series devices allows an authenticated attacker with low privileges to cause a Denial-of-Service (DoS). If an attempt is made to subscribe to an unsupported telemetry sensor path on EX2300, EX3400, EX4000, EX4100 and EX4400 via gRPC, this causes the FPC to crash. This leads to a complete service outage until the module has automatically restarted. The following log message can be seen when this issue happens: agentd[<PID>]: AGENTD_RESOURCE_NOT_FOUND: No resource name found for <sensor> This issue affects Junos OS on EX2300, EX3400, EX4000, EX4100 and EX4400 devices: * all versions before 23.2R2-S7, * 23.4 versions before 23.4R2-S8, * 24.2 versions before 24.2R2-S5, * 24.4 versions before 24.4R2.

Ein Angreifer kann die Lücke über das Netzwerk ausnutzen, mit einem normalen Benutzerkonto, ohne Zutun eines Nutzers. Bei Erfolg: hohes Risiko für Ausfälle.

Betroffene Produkte · Juniper

ProduktBetroffene Versionen
Junos OS
vor 23.2
Versionen 23.2, 23.4, 24.2, 24.4

Schwachstellenklasse

Referenzen