CVE-2026-95379

Path traversal in the certificate.deleteCertificate JSON-RPC method (POST /api/rpc) of the turbineweb web interface in Zenitel VSFF6, VSFF8, VSFF8MP, VSFF8MN, …

Auswirkung

Path traversal in the certificate.deleteCertificate JSON-RPC method (POST /api/rpc) of the turbineweb web interface in Zenitel VSFF6, VSFF8, VSFF8MP, VSFF8MN, and VSFT devices with software versions from 10.0.3.0 before 10.1.3.0 allows authenticated administrators to delete arbitrary files as root via a relative path (../) in the file_name parameter. This can be used to cause denial of service or render the device inoperable by removing critical system files, and to weaken device security by removing files such as firewall rules or certificate trust stores.

Ein Angreifer kann die Lücke über das Netzwerk ausnutzen, mit einem Administratorkonto, ohne Zutun eines Nutzers. Bei Erfolg: hohes Risiko, dass Daten oder Systeme verändert werden, hohes Risiko für Ausfälle.

Betroffene Produkte · Zenitel

ProduktBetroffene Versionen
VSFF6
ab 10.0.3.0 vor 10.1.3.0
VSFF8
ab 10.0.3.0 vor 10.1.3.0
VSFF8MN
ab 10.0.3.0 vor 10.1.3.0
VSFF8MP
ab 10.0.3.0 vor 10.1.3.0
VSFT
ab 10.0.3.0 vor 10.1.3.0