NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
153 passende Meldungen · Seite 2 von 6Index aktualisiert vor 2 Minuten · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
kritisch9.8 CVE-2022-22806 A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection i… schneider-electric · smt_series_1015_ups_firmware, schneider-electric · smc_series_1018_ups_firmware, schneider-electric · smtl_series_1026_ups_firmware +5 2022-03-09 kritisch9.8 CVE-2022-22805 A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists that could cause remote code execution when an improperl… schneider-electric · smt_series_1015_ups_firmware, schneider-electric · smc_series_1018_ups_firmware, schneider-electric · smtl_series_1026_ups_firmware +5 2022-03-09 kritisch9.1 CVE-2022-0715 A CWE-287: Improper Authentication vulnerability exists that could cause an attacker to arbitrarily change the behavior of the UPS when a key is leaked and use… schneider-electric · smt_series_1015_ups_firmware, schneider-electric · smc_series_1018_ups_firmware, schneider-electric · smtl_series_1026_ups_firmware +9 2022-03-09 kritisch9.1 CVE-2021-22823 A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IG… schneider-electric · interactive_graphical_scada_system_data_collector 2022-02-11 kritisch9.1 CVE-2021-22805 A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause deletion of arbitrary files in the context of the user running IG… schneider-electric · interactive_graphical_scada_system_data_collector 2022-02-11 kritisch9.8 CVE-2021-22803 A CWE-434: Unrestricted Upload of File with Dangerous Type vulnerability exists that could lead to remote code execution through a number of paths, when an att… schneider-electric · interactive_graphical_scada_system_data_collector 2022-02-11 kritisch9.8 CVE-2021-22802 A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could result in remote code execution due to missing length check on user suppl… schneider-electric · interactive_graphical_scada_system_data_collector 2022-02-11 kritisch9.8 CVE-2021-22801 A CWE-269: Improper Privilege Management vulnerability exists that could cause an arbitrary command execution when the software is configured with specially cr… schneider-electric · connexium_network_manager 2022-02-11 kritisch9.8 CVE-2022-24313 A CWE-120: Buffer Copy without Checking Size of Input vulnerability exists that could cause a stack-based buffer overflow potentially leading to remote code ex… schneider-electric · interactive_graphical_scada_system_data_server 2022-02-09 kritisch9.8 CVE-2022-24312 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by adding at end o… schneider-electric · interactive_graphical_scada_system_data_server 2022-02-09 kritisch9.8 CVE-2022-24311 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists that could cause modification of an existing file by inserting at be… schneider-electric · interactive_graphical_scada_system_data_server 2022-02-09 kritisch9.8 CVE-2022-24310 A CWE-190: Integer Overflow or Wraparound vulnerability exists that could cause heap-based buffer overflow, leading to denial of service and potentially remote… schneider-electric · interactive_graphical_scada_system_data_server 2022-02-09 kritisch9.8 CVE-2022-22813 A CWE-798: Use of Hard-coded Credentials vulnerability exists. schneider-electric · easergy_p141_firmware, schneider-electric · easergy_p142_firmware, schneider-electric · easergy_p143_firmware +9 2022-02-09 kritisch9.8 CVE-2022-22810 A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could allow an attacker to manipulate the admin after numerous a… schneider-electric · spacelynk_firmware, schneider-electric · wiser_for_knx_firmware, schneider-electric · fellerlynk_firmware 2022-02-09 kritisch9.8 CVE-2021-22820 A CWE-614 Insufficient Session Expiration vulnerability exists that could allow an attacker to maintain an unauthorized access over a hijacked session to the c… schneider-electric · evlink_city_evc1s22p4_firmware, schneider-electric · evlink_city_evc1s7p4_firmware, schneider-electric · evlink_parking_evw2_firmware +3 2022-01-28 kritisch9.1 CVE-2021-22704 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions p… schneider-electric · vijeo_designer, schneider-electric · ecostruxure_machine_expert 2021-09-02 kritisch9.8 CVE-2021-22772 A CWE-306: Missing Authentication for Critical Function vulnerability exists in Easergy T200 ((Modbus) SC2-04MOD-07000100 and earlier), Easergy T200 ((IEC104) … schneider-electric · t200i_firmware, schneider-electric · t200e_firmware, schneider-electric · t200p_firmware 2021-07-21 kritisch9.8 CVE-2021-22730 A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / E… schneider-electric · evlink_city_evc1s22p4_firmware, schneider-electric · evlink_city_evc1s7p4_firmware, schneider-electric · evlink_parking_evw2_firmware +3 2021-07-21 kritisch9.8 CVE-2021-22729 A CWE-259: Use of Hard-coded Password vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2… schneider-electric · evlink_city_evc1s22p4_firmware, schneider-electric · evlink_city_evc1s7p4_firmware, schneider-electric · evlink_parking_evw2_firmware +3 2021-07-21 kritisch9.8 CVE-2021-22727 A CWE-331: Insufficient Entropy vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / EVF2 / EV.… schneider-electric · evlink_city_evc1s22p4_firmware, schneider-electric · evlink_city_evc1s7p4_firmware, schneider-electric · evlink_parking_evw2_firmware +3 2021-07-21 kritisch9.8 CVE-2021-22707 A CWE-798: Use of Hard-coded Credentials vulnerability exists in EVlink City (EVC1S22P4 / EVC1S7P4 all versions prior to R8 V3.4.0.1), EVlink Parking (EVW2 / E… schneider-electric · evlink_city_evc1s22p4_firmware, schneider-electric · evlink_city_evc1s7p4_firmware, schneider-electric · evlink_parking_evw2_firmware +3 2021-07-21 kritisch9.1 CVE-2021-22779 Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), Ec… schneider-electric · ecostruxure_control_expert, schneider-electric · ecostruxure_process_expert, schneider-electric · remoteconnect +9 2021-07-14 kritisch9.8 CVE-2021-22768 A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause … schneider-electric · powerlogic_egx100_firmware, schneider-electric · powerlogic_egx300_firmware 2021-06-11 kritisch9.8 CVE-2021-22767 A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause … schneider-electric · powerlogic_egx100_firmware, schneider-electric · powerlogic_egx300_firmware 2021-06-11 kritisch9.8 CVE-2021-22765 A CWE-20: Improper Input Validation vulnerability exists in PowerLogic EGX100 (Versions 3.0.0 and newer) and PowerLogic EGX300 (All Versions) that could cause … schneider-electric · powerlogic_egx100_firmware, schneider-electric · powerlogic_egx300_firmware 2021-06-11 kritisch9.8 CVE-2021-22763 A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists in PowerLogic PM55xx, PowerLogic PM8ECC, PowerLogic EGX100 and PowerLog… schneider-electric · powerlogic_pm5560_firmware, schneider-electric · powerlogic_pm5561_firmware, schneider-electric · powerlogic_pm5562_firmware +2 2021-06-11 kritisch9.8 CVE-2021-22738 Use of a Broken or Risky Cryptographic Algorithm vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized a… schneider-electric · spacelynk_firmware, schneider-electric · homelynk_firmware 2021-05-26 kritisch9.8 CVE-2021-22737 Insufficiently Protected Credentials vulnerability exists in homeLYnk (Wiser For KNX) and spaceLYnk V2.60 and prior that could cause unauthorized access of whe… schneider-electric · spacelynk_firmware, schneider-electric · homelynk_firmware 2021-05-26 kritisch9.8 CVE-2021-22731 Weak Password Recovery Mechanism for Forgotten Password vulnerability exists on Modicon Managed Switch MCSESM* and MCSESP* V8.21 and prior which could cause an… schneider-electric · mcsesp083f23g0_firmware, schneider-electric · mcsesp083f23g0t_firmware, schneider-electric · mcsesm043f23f0_firmware +9 2021-05-26 kritisch9.8 CVE-2021-22714 A CWE-119:Improper restriction of operations within the bounds of a memory buffer vulnerability exists in PowerLogic ION7400, PM8000 and ION9000 (All versions … schneider-electric · powerlogic_ion7400_firmware, schneider-electric · powerlogic_pm8000_firmware, schneider-electric · powerlogic_ion9000_firmware 2021-03-11

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.