NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
758 passende Meldungen · Seite 1 von 26Index aktualisiert gerade eben · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
mittel6.5 CVE-2026-9718 CWE-617 Reachable Assertion vulnerability exists that could allow an authenticated attacker to trigger a denial-of-service condition, impacting system availabi… schneider-electric · powerlogic_p7_firmware 2026-06-25 hoch7.2 CVE-2026-9717 CWE-78 Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that could allow unauthorized execution of comman… schneider-electric · powerlogic_p7_firmware 2026-06-25 hoch7.5 CVE-2026-9716 CWE-476 NULL Pointer Dereference vulnerability exists that could cause a denial-of-service condition, rendering the device’s HMI and configuration functionalit… schneider-electric · powerlogic_p7_firmware 2026-06-25 mittel4.4 CVE-2026-9651 CWE-732 Incorrect Permission Assignment for Critical Resource vulnerability that could cause unauthorized disclosure of password hashes and potential account c… schneider-electric · easylogic_t150_firmware, schneider-electric · saitel_dp_firmware 2026-06-25 hoch7.5 CVE-2026-9650 CWE-522 Insufficiently Protected Credentials vulnerability that could cause unauthorized access and exposure of sensitive information when unauthenticated atta… schneider-electric · easylogic_t150_firmware, schneider-electric · saitel_dp_firmware 2026-06-25 mittel6.5 CVE-2026-8045 CWE-611 Improper Restriction of XML External Entity Reference vulnerability exists that could cause information disclosure of server-side file contents when an… schneider-electric · struxureware_data_center_expert 2026-06-09 hoch7.5 CVE-2026-6332 CWE-312: Cleartext Storage of Sensitive Information vulnerability exists that could cause the disclosure of a sensitive information which could result in revea… schneider-electric · ecostruxure_machine_expert_hvac 2026-05-14 hoch7.5 CVE-2026-6866 CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when cred… schneider-electric · ecostruxure_panel_server_pas400_firmware, schneider-electric · ecostruxure_panel_server_pas600_firmware, schneider-electric · ecostruxure_panel_server_pas600v2_firmware +2 2026-05-12 mittel6.5 CVE-2026-2405 CWE-400 Uncontrolled Resource Consumption vulnerability exists that could cause excessive troubleshooting zip file creation and denial of service when a Web Ad… schneider-electric · powerchute_serial_shutdown 2026-04-14 mittel5.3 CVE-2026-2404 CWE-116 Improper Encoding or Escaping of Output vulnerability exists that could cause log injection and forged log when an attacker alters the POST /j_security… schneider-electric · powerchute_serial_shutdown 2026-04-14 mittel4.3 CVE-2026-2403 CWE-1284 Improper Validation of Specified Quantity in Input vulnerability exists that could cause Event and Data Log truncation impacting log integrity when a … schneider-electric · powerchute_serial_shutdown 2026-04-14 mittel5.3 CVE-2026-2402 CWE-307 Improper Restriction of Excessive Authentication Attempts vulnerability exists that would allow an attacker to gain access to the user account by perfo… schneider-electric · powerchute_serial_shutdown 2026-04-14 mittel5.0 CVE-2026-2401 CWE-532 Insertion of Sensitive Information into Log File vulnerability exists that could cause confidential information to be exposed when a Web Admin user exe… schneider-electric · powerchute_serial_shutdown 2026-04-14 mittel4.3 CVE-2026-2400 CWE-93 Improper Neutralization of CRLF Sequences ('CRLF Injection') vulnerability exists that could cause application user credentials to reset when a Web Admi… schneider-electric · powerchute_serial_shutdown 2026-04-14 mittel6.1 CVE-2026-2399 CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause critical files overwritten with tex… schneider-electric · powerchute_serial_shutdown 2026-04-14 hoch8.2 CVE-2026-2273 CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exist that could cause execution of untrusted commands on the engineering works… schneider-electric · ecostruxure_automation_expert 2026-03-10 mittel6.5 CVE-2026-1286 CWE-502: Deserialization of untrusted data vulnerability exists that could lead to loss of confidentiality, integrity and potential remote code execution on wo… schneider-electric · ecostruxure_foxboro_dcs_control_software 2026-03-10 mittel5.4 CVE-2025-13902 CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause condition where authenticated… schneider-electric · modicon_m258_firmware, schneider-electric · modicon_lmc058_firmware, schneider-electric · modicon_m251_firmware +1 2026-03-10 mittel5.3 CVE-2025-13901 CWE-404 Improper Resource Shutdown or Release vulnerability exists that could cause partial Denial of Service on Machine Expert protocol when an unauthenticate… schneider-electric · modicon_m241_firmware, schneider-electric · modicon_m251_firmware, schneider-electric · modicon_m262_firmware 2026-03-10 hoch7.8 CVE-2025-11739 CWE‑502: Deserialization of Untrusted Data vulnerability exists that could cause arbitrary code execution with administrative privileges when a locally authent… schneider-electric · ecostruxure_power_monitoring_expert, schneider-electric · ecostruxure_power_operation 2026-03-10 hoch7.8 CVE-2025-13845 CWE-416: Use After Free vulnerability that could cause remote code execution when the end user imports the malicious project file (SSD file) into Rapsody. schneider-electric · ecostruxure_power_build_-_rapsody 2026-01-15 mittel5.3 CVE-2025-13844 CWE-415: Double Free vulnerability exists that could cause heap memory corruption when the end user imports a malicious project file (SSD file) shared by the a… schneider-electric · ecostruxure_power_build_-_rapsody 2026-01-15 hoch7.5 CVE-2024-9409 CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become unresponsive resulting in communication loss when a la… schneider-electric · powerlogic_pm5341_firmware, schneider-electric · powerlogic_pm5340_firmware, schneider-electric · powerlogic_pm5320_firmware 2024-11-13 kritisch9.8 CVE-2024-10575 CWE-862: Missing Authorization vulnerability exists that could cause unauthorized access when enabled on the network and potentially impacting connected device… schneider-electric · ecostruxure_it_gateway 2024-11-13 hoch7.8 CVE-2024-8422 CWE-416: Use After Free vulnerability exists that could cause arbitrary code execution, denial of service and loss of confidentiality & integrity when applicat… schneider-electric · zelio_soft_2 2024-10-08 hoch7.8 CVE-2024-8306 CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity and availability of the wo… schneider-electric · vijeo_designer, schneider-electric · vijeo_designer_embedded_in_ecostruxure_machine_expert 2024-09-11 kritisch9.8 CVE-2024-6407 CWE-200: Information Exposure vulnerability exists that could cause disclosure of credentials when a specially crafted message is sent to the device. schneider-electric · whc-5918a_firmware 2024-07-11 mittel5.4 CVE-2024-6528 CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause a vulnerability leading to a… schneider-electric · modicon_m241_firmware, schneider-electric · modicon_m251_firmware, schneider-electric · modicon_m258_firmware +2 2024-07-11 hoch7.8 CVE-2024-5681 CWE-20: Improper Input Validation vulnerability exists that could cause local denial-of-service, privilege escalation, and potentially kernel execution when a … schneider-electric · ecostruxure_foxboro_dcs_control_core_services 2024-07-11 hoch7.1 CVE-2024-5680 CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service when a malicious actor with local user access crafts … schneider-electric · ecostruxure_foxboro_dcs_control_core_services 2024-07-11

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.