NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
376 passende Meldungen · Seite 2 von 13Index aktualisiert gerade eben · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
hoch7.8 CVE-2023-3001 A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potenti… schneider-electric · igss_dashboard 2023-06-14 hoch7.0 CVE-2023-2570 A CWE-129: Improper Validation of Array Index vulnerability exists that could cause local denial-of-service, and potentially kernel execution when a malicious … schneider-electric · ecostruxure_foxboro_dcs_control_core_services 2023-06-14 hoch7.8 CVE-2023-2569 A CWE-787: Out-of-Bounds Write vulnerability exists that could cause local denial-of-service, elevation of privilege, and potentially kernel execution when a m… schneider-electric · ecostruxure_foxboro_dcs_control_core_services 2023-06-14 hoch7.8 CVE-2023-1049 A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user… schneider-electric · ecostruxure_operator_terminal_expert, schneider-electric · pro-face_blue 2023-06-14 hoch8.8 CVE-2022-46680 A CWE-319: Cleartext transmission of sensitive information vulnerability exists that could cause disclosure of sensitive information, denial of service, or mod… schneider-electric · powerlogic_ion9000_firmware, schneider-electric · powerlogic_ion7400_firmware, schneider-electric · powerlogic_pm8000_firmware +2 2023-05-22 hoch7.5 CVE-2023-25619 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating ov… schneider-electric · modicon_m580_firmware, schneider-electric · modicon_m340_firmware, schneider-electric · modicon_momentum_unity_m1e_processor_firmware +4 2023-04-19 hoch7.2 CVE-2023-29410 A CWE-20: Improper Input Validation vulnerability exists that could allow an authenticated attacker to gain the same privilege as the application on the server… schneider-electric · insighthome_firmware, schneider-electric · insightfacility_firmware, schneider-electric · conext_gateway_firmware 2023-04-18 hoch7.5 CVE-2023-29413 A CWE-306: Missing Authentication for Critical Function vulnerability exists that could cause Denial-of-Service when accessed by an unauthenticated user on the… schneider-electric · apc_easy_ups_online_monitoring_software, schneider-electric · easy_ups_online_monitoring_software 2023-04-18 hoch7.8 CVE-2023-25554 A CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') vulnerability exists that allows a local privilege escalat… schneider-electric · struxureware_data_center_expert 2023-04-18 hoch8.1 CVE-2023-25552 A CWE-862: Missing Authorization vulnerability exists that could allow viewing of unauthorized content, changes or deleting of content, or performing unauthori… schneider-electric · struxureware_data_center_expert 2023-04-18 hoch7.2 CVE-2023-25550 A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows remote code execution via the “hostname” parameter when ma… schneider-electric · struxureware_data_center_expert 2023-04-18 hoch7.2 CVE-2023-25549 A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that allows for remote code execution when using a parameter of the DC… schneider-electric · struxureware_data_center_expert 2023-04-18 hoch8.8 CVE-2023-25548 A CWE-863: Incorrect Authorization vulnerability exists that could allow access to device credentials on specific DCE endpoints not being properly secured when… schneider-electric · struxureware_data_center_expert 2023-04-18 hoch8.8 CVE-2023-25547 A CWE-863: Incorrect Authorization vulnerability exists that could allow remote code execution on upload and install packages when a hacker is using a low priv… schneider-electric · struxureware_data_center_expert 2023-04-18 hoch7.5 CVE-2022-43377 A CWE-307: Improper Restriction of Excessive Authentication Attempts vulnerability exists that could cause account takeover when a brute force attack is perfor… schneider-electric · netbotz_355_firmware, schneider-electric · netbotz_450_firmware, schneider-electric · netbotz_455_firmware +2 2023-04-18 hoch7.6 CVE-2022-43376 A CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability exists that could cause code and session manipulat… schneider-electric · netbotz_355_firmware, schneider-electric · netbotz_450_firmware, schneider-electric · netbotz_455_firmware +2 2023-04-18 hoch8.3 CVE-2023-25556 A CWE-287: Improper Authentication vulnerability exists that could allow a device to be compromised when a key of less than seven digits is entered and the att… schneider-electric · merten_instabus_tastermodul_1fach_system_m_firmware, schneider-electric · merten_instabus_tastermodul_2fach_system_m_firmware, schneider-electric · merten_tasterschnittstelle_4fach_plus_firmware +4 2023-04-18 hoch8.8 CVE-2023-27976 A CWE-668: Exposure of Resource to Wrong Sphere vulnerability exists that could cause remote code execution when a valid user visits a malicious link provided … schneider-electric · ecostruxure_control_expert 2023-04-18 hoch7.8 CVE-2023-27984 A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code executio… schneider-electric · custom_reports, schneider-electric · igss_dashboard, schneider-electric · igss_data_server 2023-03-21 hoch7.8 CVE-2023-27981 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Custom Reports that could cause a remote code execution when a vi… schneider-electric · custom_reports, schneider-electric · igss_dashboard, schneider-electric · igss_data_server 2023-03-21 hoch7.8 CVE-2023-27978 A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potenti… schneider-electric · custom_reports, schneider-electric · igss_dashboard, schneider-electric · igss_data_server 2023-03-21 hoch8.8 CVE-2023-27982 A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS … schneider-electric · custom_reports, schneider-electric · igss_dashboard, schneider-electric · igss_data_server 2023-03-21 hoch8.8 CVE-2023-27980 A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious repo… schneider-electric · custom_reports, schneider-electric · igss_dashboard, schneider-electric · igss_data_server 2023-03-21 hoch7.8 CVE-2022-4062 A CWE-285: Improper Authorization vulnerability exists that could cause unauthorized access to certain software functions when an attacker gets access to local… schneider-electric · ecostruxure_power_commission 2023-02-01 hoch7.8 CVE-2022-42973 A CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause local privilege escalation when local attacker connects to the database. schneider-electric · apc_easy_ups_online_monitoring_software, schneider-electric · easy_ups_online_monitoring_software 2023-02-01 hoch7.8 CVE-2022-42972 A CWE-732: Incorrect Permission Assignment for Critical Resource vulnerability exists that could cause local privilege escalation when a local attacker modifie… schneider-electric · apc_easy_ups_online_monitoring_software, schneider-electric · easy_ups_online_monitoring_software 2023-02-01 hoch7.5 CVE-2021-22786 A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communi… schneider-electric · modicon_m340_bmxp341000_firmware, schneider-electric · modicon_m340_bmxp342000_firmware, schneider-electric · modicon_m340_bmxp342010_firmware +9 2023-02-01 hoch7.5 CVE-2023-22611 A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are s… schneider-electric · ecostruxure_geo_scada_expert_2019, schneider-electric · ecostruxure_geo_scada_expert_2020, schneider-electric · ecostruxure_geo_scada_expert_2021 2023-01-31 hoch8.1 CVE-2022-45789 A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hija… schneider-electric · ecostruxure_control_expert, schneider-electric · ecostruxure_process_expert, schneider-electric · modicon_m340_bmxp341000_firmware +9 2023-01-31 hoch7.9 CVE-2022-32748 A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure d… schneider-electric · ecostruxure_cybersecurity_admin_expert 2023-01-30

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.