NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
103 passende Meldungen · Seite 3 von 4Index aktualisiert gerade eben · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
hoch7.5 CVE-2022-1778 Improper Input Validation vulnerability in Hitachi Energy MicroSCADA X SYS600 while reading a specific configuration file causes a buffer-overflow that causes … hitachienergy · microscada_x_sys600 2022-09-14 hoch8.5 CVE-2022-29490 Improper Authorization vulnerability exists in the Workplace X WebUI of the Hitachi Energy MicroSCADA X SYS600 allows an authenticated user to execute any Micr… hitachienergy · microscada_x_sys600 2022-09-12 mittel5.0 CVE-2021-40336 A vulnerability exists in the http web interface where the web interface does not validate data in an HTTP header. hitachienergy · modular_switchgear_monitoring_firmware 2022-07-25 mittel5.0 CVE-2021-40335 A vulnerability exists in the HTTP web interface where the web interface does not sufficiently verify if a well-formed, valid, consistent request was intention… hitachienergy · modular_switchgear_monitoring_firmware 2022-07-25 mittel6.7 CVE-2021-35532 A vulnerability exists in the file upload validation part of Hitachi Energy TXpert Hub CoreTec 4 product. hitachienergy · txpert_hub_coretec_4_firmware 2022-06-07 mittel6.7 CVE-2021-35531 Improper Input Validation vulnerability in a particular configuration setting field of Hitachi Energy TXpert Hub CoreTec 4 product, allows an attacker with acc… hitachienergy · txpert_hub_coretec_4_firmware 2022-06-07 mittel6.0 CVE-2021-35530 A vulnerability in the application authentication and authorization mechanism in Hitachi Energy's TXpert Hub CoreTec 4, that depends on a token validation of t… hitachienergy · txpert_hub_coretec_4_firmware 2022-06-07 hoch7.5 CVE-2022-28613 A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. abb · rtu500_firmware, hitachienergy · rtu500_firmware 2022-05-02 mittel5.5 CVE-2021-27416 An attacker could exploit this vulnerability in Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 by tri… hitachienergy · ellipse_enterprise_asset_management 2022-03-11 mittel5.5 CVE-2021-27414 An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a mali… hitachienergy · ellipse_enterprise_asset_management 2022-03-11 hoch8.6 CVE-2021-40334 Missing Handler vulnerability in the proprietary management protocol (port TCP 5558) of Hitachi Energy FOX61x, XCM20 allows an attacker that exploits the vulne… hitachienergy · fox615_firmware, hitachienergy · xcm20_firmware 2021-12-02 kritisch9.0 CVE-2021-40333 Weak Password Requirements vulnerability in Hitachi Energy FOX61x, XCM20 allows an attacker to gain unauthorized access to the Data Communication Network (DCN)… hitachienergy · fox615_firmware, hitachienergy · xcm20_firmware 2021-12-02 hoch7.5 CVE-2021-35533 Improper Input Validation vulnerability in the APDU parser in the Bidirectional Communication Interface (BCI) IEC 60870-5-104 function of Hitachi Energy RTU500… hitachienergy · rtu500_firmware 2021-11-26 hoch7.2 CVE-2021-35534 Insufficient security control vulnerability in internal database access mechanism of Hitachi Energy Relion 670/650/SAM600-IO, Relion 650, GMS600, PWC600 allows… hitachienergy · gms600_firmware, hitachienergy · relion_670_firmware, hitachienergy · relion_650_firmware +2 2021-11-18 hoch8.1 CVE-2021-35535 Insecure Boot Image vulnerability in Hitachi Energy Relion Relion 670/650/SAM600-IO series allows an attacker who manages to get access to the front network po… hitachienergy · relion_670_firmware, hitachienergy · relion_650_firmware, hitachienergy · relion_sam600-io_firmware 2021-11-18 hoch7.2 CVE-2021-35528 Improper Access Control vulnerability in the application authentication and authorization of Hitachi Energy Retail Operations, Counterparty Settlement and Bill… hitachienergy · counterparty_settlements_and_billing, hitachienergy · retail_operations 2021-11-17 hoch7.7 CVE-2021-35529 Insufficiently Protected Credentials vulnerability in client environment of Hitachi ABB Power Grids Retail Operations and Counterparty Settlement Billing (CSB)… hitachienergy · counterparty_settlement_and_billing, hitachienergy · retail_operations 2021-08-20 hoch7.5 CVE-2021-35527 Password autocomplete vulnerability in the web application password field of Hitachi ABB Power Grids eSOMS allows attacker to gain access to user credentials t… hitachienergy · esoms 2021-07-14 hoch7.5 CVE-2021-27196 Improper Input Validation vulnerability in Hitachi ABB Power Grids Relion 670 Series, Relion 670/650 Series, Relion 670/650/SAM600-IO, Relion 650, REB500, RTU5… hitachienergy · relion_670_firmware, hitachienergy · relion_650_firmware, hitachienergy · relion_sam600-io_firmware +6 2021-06-14 hoch7.5 CVE-2021-26845 Information Exposure vulnerability in Hitachi ABB Power Grids eSOMS allows unauthorized user to gain access to report data if the URL used to access the report… hitachienergy · esoms 2021-06-14 kritisch9.8 CVE-2019-5620 ABB MicroSCADA Pro SYS600 version 9.3 suffers from an instance of CWE-306: Missing Authentication for Critical Function. hitachienergy · microscada_pro_sys600 2020-04-29 mittel5.9 CVE-2019-19097 ABB eSOMS versions 4.0 to 6.0.3 accept connections using medium strength ciphers. hitachienergy · esoms 2020-04-02 mittel6.1 CVE-2019-19096 The Redis data structure component used in ABB eSOMS versions 6.0 to 6.0.2 stores credentials in clear text. hitachienergy · esoms 2020-04-02 mittel5.4 CVE-2019-19095 Lack of adequate input/output validation for ABB eSOMS versions 4.0 to 6.0.2 might allow an attacker to attack such as stored cross-site scripting by storing m… hitachienergy · esoms 2020-04-02 hoch7.6 CVE-2019-19094 Lack of input checks for SQL queries in ABB eSOMS versions 3.9 to 6.0.3 might allow an attacker SQL injection attacks against the backend database. hitachienergy · esoms 2020-04-02 mittel6.5 CVE-2019-19093 eSOMS versions 4.0 to 6.0.3 do not enforce password complexity settings, potentially resulting in lower access security due to insecure user passwords. hitachienergy · esoms 2020-04-02 niedrig3.5 CVE-2019-19092 ABB eSOMS versions 4.0 to 6.0.3 use ASP.NET Viewstate without Message Authentication Code (MAC). hitachienergy · esoms 2020-04-02 mittel4.3 CVE-2019-19091 For ABB eSOMS versions 4.0 to 6.0.3, HTTPS responses contain comments with sensitive information about the application. hitachienergy · esoms 2020-04-02 niedrig3.5 CVE-2019-19090 For ABB eSOMS versions 4.0 to 6.0.2, the Secure Flag is not set in the HTTP response header. hitachienergy · esoms 2020-04-02 mittel6.1 CVE-2019-19089 For ABB eSOMS versions 4.0 to 6.0.3, the X-Content-Type-Options Header is missing in the HTTP response, potentially causing the response body to be interpreted… hitachienergy · esoms 2020-04-02

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.