NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
23 passende Meldungen · Seite 1 von 1Index aktualisiert gerade eben · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
hoch7.8 CVE-2024-11611 AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability. automationdirect · c-more_ea9-t10cl_firmware, automationdirect · c-more_ea9-t10wcl_firmware, automationdirect · c-more_ea9-t12cl_firmware +6 2025-01-30 hoch7.8 CVE-2024-11610 AutomationDirect C-More EA9 EAP9 File Parsing Memory Corruption Remote Code Execution Vulnerability. automationdirect · c-more_ea9-t10cl_firmware, automationdirect · c-more_ea9-t10wcl_firmware, automationdirect · c-more_ea9-t12cl_firmware +6 2025-01-30 hoch7.8 CVE-2024-11609 AutomationDirect C-More EA9 EAP9 File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. automationdirect · c-more_ea9-t10cl_firmware, automationdirect · c-more_ea9-t10wcl_firmware, automationdirect · c-more_ea9-t12cl_firmware +6 2025-01-30 hoch8.2 CVE-2024-24959 Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware 2024-05-28 hoch8.2 CVE-2024-24958 Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware 2024-05-28 hoch8.2 CVE-2024-24957 Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware 2024-05-28 hoch8.2 CVE-2024-24956 Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware 2024-05-28 hoch8.2 CVE-2024-24955 Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware 2024-05-28 hoch8.2 CVE-2024-24954 Several out-of-bounds write vulnerabilities exist in the Programming Software Connection FileSystem API functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware 2024-05-28 hoch8.2 CVE-2024-24947 A heap-based buffer overflow vulnerability exists in the Programming Software Connection CurrDir functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware, automationdirect · p3-550_firmware, automationdirect · p3-530_firmware +3 2024-05-28 hoch8.2 CVE-2024-24946 A heap-based buffer overflow vulnerability exists in the Programming Software Connection CurrDir functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware, automationdirect · p3-550_firmware, automationdirect · p3-530_firmware +3 2024-05-28 hoch7.5 CVE-2024-24851 A heap-based buffer overflow vulnerability exists in the Programming Software Connection FiBurn functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware, automationdirect · p3-550_firmware, automationdirect · p3-530_firmware +3 2024-05-28 hoch7.5 CVE-2024-23315 A read-what-where vulnerability exists in the Programming Software Connection IMM 01A1 Memory Read functionality of AutomationDirect P3-550E 1.2.10.9. automationdirect · p3-550e_firmware, automationdirect · p3-550_firmware, automationdirect · p3-530_firmware +3 2024-05-28 hoch7.5 CVE-2024-25136 There is a function in AutomationDirect C-MORE EA9 HMI that allows an attacker to send a relative path in the URL without proper sanitizing of the content. 2024-03-26 hoch7.8 CVE-2022-2006 AutomationDirect DirectLOGIC has a DLL vulnerability in the install directory that may allow an attacker to execute code during the installation process. automationdirect · c-more_ea9-t6cl_firmware, automationdirect · c-more_ea9-t6cl-r_firmware, automationdirect · c-more_ea9-t7cl_firmware +9 2022-08-31 hoch7.5 CVE-2022-2005 AutomationDirect C-more EA9 HTTP webserver uses an insecure mechanism to transport credentials from client to web server, which may allow an attacker to obtain… automationdirect · c-more_ea9-t6cl_firmware, automationdirect · c-more_ea9-t6cl-r_firmware, automationdirect · c-more_ea9-t7cl_firmware +9 2022-08-31 hoch7.5 CVE-2022-2004 AutomationDirect DirectLOGIC is vulnerable to a a specially crafted packet can be sent continuously to the PLC to prevent access from DirectSoft and other devi… automationdirect · d0-06dd1_firmware, automationdirect · d0-06dd2_firmware, automationdirect · d0-06dr_firmware +6 2022-08-31 hoch7.7 CVE-2022-2003 AutomationDirect DirectLOGIC is vulnerable to a specifically crafted serial message to the CPU serial port that will cause the PLC to respond with the PLC pass… automationdirect · d0-06dd1_firmware, automationdirect · d0-06dd2_firmware, automationdirect · d0-06dr_firmware +6 2022-08-31 hoch7.5 CVE-2021-32982 Automation Direct CLICK PLC CPU Modules: C0-1x CPUs with firmware prior to v3.00 passwords are sent as plaintext during unlocking and project transfers. automationdirect · c0-10dd1e-d_firmware, automationdirect · c0-10dd2e-d_firmware, automationdirect · c0-10dre-d_firmware +9 2022-04-04 hoch7.5 CVE-2021-32978 The programming protocol allows for a previously entered password and lock state to be read by an attacker. automationdirect · c0-10dd1e-d_firmware, automationdirect · c0-10dd2e-d_firmware, automationdirect · c0-10dre-d_firmware +9 2022-04-04 hoch7.5 CVE-2020-10922 This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch scre… automationdirect · c-more_hmi_ea9_firmware 2020-07-23 hoch7.5 CVE-2020-10918 This vulnerability allows remote attackers to bypass authentication on affected installations of C-MORE HMI EA9 Firmware version 6.52 touch screen panels. automationdirect · c-more_hmi_ea9_firmware 2020-07-23 hoch7.8 CVE-2017-14020 In AutomationDirect CLICK Programming Software (Part Number C0-PGMSW) Versions 2.10 and prior; C-More Programming Software (Part Number EA9-PGMSW) Versions 6.3… automationdirect · click_plc_firmware, automationdirect · c-more_plc_firmware, automationdirect · c-more_micro_firmware +2 2017-11-13

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.