SchweregradIDTitelBetroffenAlter
hoch8.1 CVE-2026-4272 Missing Authentication for Critical Function vulnerability in Honeywell Handheld Scanners allows Authentication Abuse.This issue affects Handheld Scanners: fro… 2026-04-05 hoch8.2 CVE-2025-3947 The Honeywell Experion PKS contains an Integer Underflow vulnerability in the component Control Data Access (CDA). 2025-07-10 hoch8.2 CVE-2025-3946 The Honeywell Experion PKS and OneWireless WDM contains a Deployment of Wrong Handler vulnerability in the component Control Data Access (CDA). 2025-07-10 hoch8.6 CVE-2025-2521 The Honeywell Experion PKS and OneWireless WDM contains a Memory Buffer vulnerability in the component Control Data Access (CDA). 2025-07-10 hoch7.5 CVE-2025-2520 The Honeywell Experion PKS contains an Uninitialized Variable in the common Epic Platform Analyzer (EPA) communications. 2025-07-10 hoch8.8 CVE-2024-2422 LenelS2 NetBox access control and event monitoring system was discovered to contain an authenticated RCE in versions prior to and including 5.6.1, which allows… honeywell · lenels2_netbox 2024-05-30 hoch8.8 CVE-2023-51603 Honeywell Saia PG5 Controls Suite CAB File Parsing Directory Traversal Remote Code Execution Vulnerability. honeywell · saia_pg5_controls_suite 2024-05-03 hoch8.8 CVE-2023-51599 Honeywell Saia PG5 Controls Suite Directory Traversal Remote Code Execution Vulnerability. honeywell · saia_pg5_controls_suite 2024-05-03 hoch8.1 CVE-2023-1841 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Honeywell MPA2 Access Panel (Web server modules) allows X… honeywell · mpa2_firmware 2024-02-29 hoch7.8 CVE-2023-6179 Honeywell ProWatch, 4.5, including all Service Pack versions, contain a Vulnerability in Application Server's executable folder(s). honeywell · prowatch 2023-11-17 hoch7.5 CVE-2023-26597 Controller DoS due to buffer overflow in the handling of a specially crafted message received by the controller. honeywell · c300_firmware 2023-07-13 hoch7.5 CVE-2023-25948 Server information leak of configuration data when an error is generated in response to a specially crafted message. honeywell · experion_server, honeywell · experion_station, honeywell · engineering_station +1 2023-07-13 hoch7.5 CVE-2023-24474 Experion server may experience a DoS due to a heap overflow which could occur when handling a specially crafted message honeywell · experion_server, honeywell · experion_station, honeywell · engineering_station +1 2023-07-13 hoch7.5 CVE-2023-22435 Experion server may experience a DoS due to a stack overflow when handling a specially crafted message. honeywell · experion_server, honeywell · experion_station, honeywell · engineering_station +1 2023-07-13 hoch8.3 CVE-2023-3243 ** UNSUPPORTED WHEN ASSIGNED ** [An attacker can capture an authenticating hash and utilize it to create new sessions. honeywell · alerton_bcm-web_firmware 2023-06-28 hoch7.5 CVE-2021-38399 Honeywell Experion PKS C200, C200E, C300, and ACE controllers are vulnerable to relative path traversal, which may allow an attacker access to unauthorized fil… honeywell · c200_firmware, honeywell · c200e_firmware, honeywell · c300_firmware +1 2022-10-28 hoch8.8 CVE-2022-2333 If an attacker manages to trick a valid user into loading a malicious DLL, the attacker may be able to achieve code execution in Honeywell SoftMaster version 4… honeywell · softmaster 2022-09-16 hoch8.1 CVE-2022-30319 Saia Burgess Controls (SBC) PCD through 2022-05-06 allows Authentication bypass. honeywell · saia_pg5_controls_suite 2022-07-28 hoch7.5 CVE-2022-30313 Honeywell Experion PKS Safety Manager through 2022-05-06 has Missing Authentication for a Critical Function. honeywell · safety_manager_firmware 2022-07-28 hoch8.0 CVE-2022-30244 Honeywell Alerton Ascent Control Module (ACM) through 2022-05-04 allows unauthenticated programming writes from remote users. honeywell · alerton_ascent_control_module_firmware 2022-07-15 hoch8.8 CVE-2022-30243 Honeywell Alerton Visual Logic through 2022-05-04 allows unauthenticated programming writes from remote users. honeywell · alterton_visual_logic_firmware 2022-07-15 hoch7.5 CVE-2021-39364 Honeywell HDZP252DI 1.00.HW02.4 and HBW2PER1 1.000.HW01.3 devices allow command spoofing (for camera control) after ARP cache poisoning has been achieved. honeywell · hdzp252di_firmware, honeywell · hbw2per1_firmware 2022-02-24 hoch7.5 CVE-2020-27295 The affected product has uncontrolled resource consumption issues, which may allow an attacker to cause a denial-of-service condition on the OPC UA Tunneller (… honeywell · opc_ua_tunneller 2021-01-26 hoch7.5 CVE-2020-27274 Some parsing functions in the affected product do not check the return value of malloc and the thread handling the message is forced to close, which may lead t… honeywell · opc_ua_tunneller 2021-01-26 hoch7.5 CVE-2020-10628 ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes unencrypted passwords on the network. honeywell · controledge_plc_firmware, honeywell · controledge_rtu_firmware 2020-06-26 hoch7.5 CVE-2020-10624 ControlEdge PLC (R130.2, R140, R150, and R151) and RTU (R101, R110, R140, R150, and R151) exposes a session token on the network. honeywell · controledge_plc_firmware, honeywell · controledge_rtu_firmware 2020-06-26 hoch8.8 CVE-2020-6982 In Honeywell WIN-PAK 4.7.2, Web and prior versions, the header injection vulnerability has been identified, which may allow remote code execution. honeywell · win-pak 2020-03-24 hoch7.2 CVE-2020-6978 In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable due to the usage of old jQuery libraries. honeywell · win-pak 2020-03-24 hoch8.8 CVE-2020-7005 In Honeywell WIN-PAK 4.7.2, Web and prior versions, the affected product is vulnerable to a cross-site request forgery, which may allow an attacker to remotely… honeywell · win-pak 2020-03-24 hoch7.8 CVE-2020-6968 Honeywell INNCOM INNControl 3 allows workstation users to escalate application user privileges through the modification of local configuration files. honeywell · inncom_inncontrol_firmware 2020-02-20

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.