NetSight
high7.1

CVE-2026-82948

The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an attacker to replay the static commands to im…

Impact

The Guardian 2 alarm unit lacks a mechanism to authenticate control commands sent over 433.92 MHz, which allows an attacker to replay the static commands to impersonate activity.  The attacker can also disarm or arm the system at will if a Nexsmart keypad (product link) is in use, thus compromising the functionality of the alarm system completely.

An attacker can exploit this from the same local network, without logging in, without any action by a user. If it succeeds: high risk of data or systems being changed.

Affected products · Onyx Cookware ApS

ProductAffected versions
Nexsmart Guardian 2 (Alarm system)
Version 0

Weakness classification

References