NetSight

Security Dashboard

A live picture of new vulnerabilities, flaws exploited in the wild and malicious packages.

Reset
103 matching advisories · page 1 of 4Index updated just now · Subscribe · RSS
SeverityIDTitleAffectedAge
high7.8 CVE-2026-9854 A vulnerability exists in SYS600 RBAC mechanism where users having access to the engineering tools could elevate their privileges to administrator level on the… hitachienergy · microscada_x_sys600 2026-09-03 high7.8 CVE-2026-9853 A vulnerability exists in SYS600 which allows any user authenticated to the operating system of the server hosting the application to read and modify applicati… hitachienergy · microscada_x_sys600 2026-09-03 high7.8 CVE-2026-9852 A CSV injection vulnerability exists in SYS600. hitachienergy · microscada_x_sys600 2026-09-03 high8.1 CVE-2026-2460 A vulnerability exists in REB500 for an authenticated user with low-level privileges to access and alter the content of directories by using the DAC protocol t… hitachienergy · reb500_firmware 2026-02-24 high8.1 CVE-2026-2459 A vulnerability exists in REB500 for an authenticated user with Installer role to access and alter the contents of directories that the role is not authorized … hitachienergy · reb500_firmware 2026-02-24 high7.5 CVE-2026-1773 IEC 60870-5-104 used in RTU500: Potential Denial of Service impact on reception of invalid U-format frame. hitachienergy · rtu540_firmware, hitachienergy · rtu560_firmware, hitachienergy · rtu520_firmware +1 2026-02-24 medium5.3 CVE-2026-1772 RTU500 web interface: An unprivileged user can read user management information. hitachienergy · rtu520_firmware, hitachienergy · rtu530_firmware, hitachienergy · rtu540_firmware +1 2026-02-24 medium6.5 CVE-2025-39205 A vulnerability exists in the IEC 61850 in MicroSCADA X SYS600 product. hitachienergy · microscada_x_sys600 2025-06-24 medium6.5 CVE-2025-39204 A vulnerability exists in the Web interface of the MicroSCADA X SYS600 product. hitachienergy · microscada_x_sys600 2025-06-24 medium6.5 CVE-2025-39203 A vulnerability exists in the IEC 61850 of the MicroSCADA X SYS600 product. hitachienergy · microscada_x_sys600 2025-06-24 high7.3 CVE-2025-39202 A vulnerability exists in in the Monitor Pro interface of the MicroSCADA X SYS600 product. hitachienergy · microscada_x_sys600 2025-06-24 medium6.1 CVE-2025-39201 A vulnerability exists in MicroSCADA X SYS600 product. hitachienergy · microscada_x_sys600 2025-06-24 low2.7 CVE-2024-41156 Profile files from TRO600 series radios are extracted in plain-text and encrypted file formats. hitachienergy · tro610_firmware, hitachienergy · tro620_firmware, hitachienergy · tro670_firmware 2024-10-29 high7.2 CVE-2024-41153 Command injection vulnerability in the Edge Computing UI for the TRO600 series radios that allows for the execution of arbitrary system commands. hitachienergy · tro610_firmware, hitachienergy · tro620_firmware, hitachienergy · tro670_firmware 2024-10-29 medium4.3 CVE-2024-7941 An HTTP parameter may contain a URL value and could cause the web application to redirect the request to the specified URL. hitachienergy · microscada_x_sys600 2024-08-27 high8.3 CVE-2024-7940 The product exposes a service that is intended for local only to all network interfaces without any authentication. hitachienergy · microscada_x_sys600 2024-08-27 critical9.9 CVE-2024-4872 A vulnerability exists in the query validation of the MicroSCADA Pro/X SYS600 product. hitachienergy · microscada_pro_sys600, hitachienergy · microscada_x_sys600 2024-08-27 high8.2 CVE-2024-3982 An attacker with local access to machine where MicroSCADA X SYS600 is installed, could enable the session logging supporting the product and try to exploit a s… hitachienergy · microscada_x_sys600 2024-08-27 critical9.9 CVE-2024-3980 The MicroSCADA Pro/X SYS600 product allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. hitachienergy · microscada_pro_sys600, hitachienergy · microscada_x_sys600 2024-08-27 medium4.1 CVE-2024-28024 A vulnerability exists in the FOXMAN-UN/UNEM in which sensitive information is stored in cleartext within a resource that might be accessible to another contro… hitachienergy · foxman-un, hitachienergy · unem 2024-06-11 medium6.5 CVE-2024-28022 A vulnerability exists in the UNEM server / APIGateway that if exploited allows a malicious user to perform an arbitrary number of authentication attempts usin… hitachienergy · foxman-un, hitachienergy · unem 2024-06-11 high8.0 CVE-2024-28020 A user/password reuse vulnerability exists in the FOXMAN-UN/UNEM application and server management. hitachienergy · foxman-un, hitachienergy · unem 2024-06-11 critical10.0 CVE-2024-2013 An authentication bypass vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway component that if exploited allows attackers without any access to int… hitachienergy · foxman-un, hitachienergy · unem 2024-06-11 critical9.1 CVE-2024-2012 vulnerability exists in the FOXMAN-UN/UNEM server / API Gateway that if exploited an attacker could use to allow unintended commands or code to be executed on … hitachienergy · foxman-un, hitachienergy · unem 2024-06-11 high8.6 CVE-2024-2011 A heap-based buffer overflow vulnerability exists in the FOXMAN-UN/UNEM that if exploited will generally lead to a denial of service but can be used to execute… hitachienergy · foxman-un, hitachienergy · unem 2024-06-11 high7.4 CVE-2024-28021 A vulnerability exists in the FOXMAN-UN/UNEM server that affects the message queueing mechanism’s certificate validation. hitachienergy · foxman-un, hitachienergy · foxman_un, hitachienergy · unem 2024-06-11 medium4.5 CVE-2022-3864 A vulnerability exists in the Relion update package signature validation. hitachienergy · relion_650_firmware, hitachienergy · relion_670_firmware, hitachienergy · relion_sam600-io_firmware 2024-01-04 high7.5 CVE-2022-2081 A vulnerability exists in the HCI Modbus TCP function included in the product versions listed above. hitachienergy · rtu520_firmware, hitachienergy · rtu530_firmware, hitachienergy · rtu540_firmware +1 2024-01-04 medium5.9 CVE-2023-6711 Vulnerability exists in SCI IEC 60870-5-104 and HCI IEC 60870-5-104 that affects the RTU500 series product versions listed below. hitachienergy · rtu500_firmware 2023-12-19 high7.4 CVE-2023-1514 A vulnerability exists in the component RTU500 Scripting interface. hitachienergy · rtu500_scripting_interface 2023-12-19

Get notifications

Subscribe to new vulnerabilities and early warnings from the last seven days. Pick what matters to your stack and copy the address into any feed reader. More filters appear when you pick a type.

Format:
Open feed

Early warnings are advisories that are published before or without a CVE number, for example malicious packages, advisories with a CVE still pending and reports that are not reviewed yet. Confidence says how well an entry is checked: high, medium or low.

About this dashboard

The dashboard keeps its own index of security advisories and refreshes it every 30 minutes. It merges the national vulnerability database, package advisories, malware reports and the catalog of vulnerabilities that are exploited in the wild into one record per issue. Reports about the same flaw are combined, so nothing is listed twice.

Open any entry for the full record: description, severity vector, affected packages and versions, fixed versions, weakness class, exploitation probability and references.

Sources: the GitHub Advisory Database (reviewed advisories, malware reports and unreviewed reports), the National Vulnerability Database, the CVE Program (cve.org) for brand-new records, the OpenSSF malicious packages list, the CISA catalog of Known Exploited Vulnerabilities and Microsoft's blocklist of malicious VS Code extensions. Every entry names its sources on its detail page.

This product uses the NVD API but is not endorsed or certified by the NVD.

Reading the figures

  • Threat level: a rating computed from three numbers shown next to it: critical advisories in the last 24 hours, vulnerabilities newly confirmed as exploited this week and malware reports this week. It is a quick orientation, not an official warning level.
  • Severity: scores from 9.0 are critical, 7.0 to 8.9 high, 4.0 to 6.9 medium and 0.1 to 3.9 low. Severity describes how bad a flaw is in general. It does not know whether the component is reachable in your environment.
  • Known exploited: exploitation has been observed in real attacks. These are the entries to patch first. Entries with a fix deadline show how many days are left.
  • Early warnings: advisories that appear before or without a CVE number, for example malicious packages, reviewed advisories with a CVE still pending and reports that are not reviewed yet.
  • Priority queue: critical and high advisories of the last 7 days and everything newly exploited, ordered by exploitation status, severity and score.

Questions

Where does the data come from?
From public vulnerability databases, package advisories and the catalog of exploited vulnerabilities. NetSight collects them into its own index every 30 minutes and merges duplicates.
How do I check whether I am affected?
Search for your product or package name, open the record and compare your installed version with the affected and fixed versions. A product name alone does not mean your version is affected.
What does known exploited mean?
Exploitation of this vulnerability has been observed in real attacks. Such entries carry a date they were confirmed and, where one exists, a deadline for applying the fix.
What is an early warning?
An advisory that is published before or without a CVE number, such as a malicious package or a reviewed advisory whose CVE is still pending. They give you a head start, but the details can change.
Is a high severity always more urgent than a low one?
No. Severity measures technical impact in general. Exposure of the affected system, observed exploitation and the exploitation probability matter as much.
Can I follow new advisories automatically?
Yes. Use the notification builder further down to create an RSS, Atom or JSON feed filtered by severity, technology, ecosystem or exploitation status.