NetSight

Sicherheitslage

Ein aktuelles Lagebild zu neuen Schwachstellen, aktiv ausgenutzten Lücken und schädlichen Paketen.

Zurücksetzen
35 passende Meldungen · Seite 1 von 2Index aktualisiert vor 2 Minuten · Abonnieren · RSS
SchweregradIDTitelBetroffenAlter
mittel6.8 CVE-2025-4397 Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. 2026-05-07 mittel6.8 CVE-2025-4386 Medtronic MyCareLink Patient Monitor has an internal serial interface, which allows an attacker with physical access to access a login prompt via a UART termin… 2026-05-07 niedrig2.2 CVE-2025-12997 Insecure Direct Object Reference vulnerability in Medtronic CareLink Network which allows an authenticated attacker with access to specific device and user inf… medtronic · carelink_network 2025-12-04 mittel4.1 CVE-2025-12996 Medtronic CareLink Network allows a local attacker with access to log files on an internal API server to view plaintext passwords from errors logged under cert… medtronic · carelink_network 2025-12-04 hoch8.1 CVE-2025-12995 Medtronic CareLink Network allows an unauthenticated remote attacker to perform a brute force attack on an API endpoint that could be used to determine a valid… medtronic · carelink_network 2025-12-04 mittel5.3 CVE-2025-12994 Medtronic CareLink Network allows an unauthenticated remote attacker to initiate a request for security questions to an API endpoint that could be used to dete… medtronic · carelink_network 2025-12-04 mittel6.8 CVE-2025-4395 Medtronic MyCareLink Patient Monitor has a built-in user account with an empty password, which allows an attacker with physical access to log in with no passwo… 2025-07-24 mittel6.8 CVE-2025-4394 Medtronic MyCareLink Patient Monitor uses an unencrypted filesystem on internal storage, which allows an attacker with physical access to read and modify files. 2025-07-24 mittel6.5 CVE-2025-4393 Medtronic MyCareLink Patient Monitor has an internal service that deserializes data, which allows a local attacker to interact with the service by crafting a b… 2025-07-24 kritisch9.8 CVE-2023-31222 Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthori… medtronic · paceart_optima 2023-06-29 mittel6.4 CVE-2023-25931 Medtronic identified that the Pelvic Health clinician apps, which are installed on the Smart Programmer mobile device, have a password vulnerability that requi… medtronic · interstim_x_clinician, medtronic · micro_clinician 2023-03-01 mittel4.8 CVE-2022-32537 A vulnerability exists which could allow an unauthorized user to learn aspects of the communication protocol used to pair system components while the pump is b… medtronic · guardian_link_2_transmitter_mmt-7730_firmware, medtronic · guardian_link_2_transmitter_mmt-7731_firmware, medtronic · guardian_link_2_transmitter_mmt-7738_firmware +9 2022-12-12 hoch8.8 CVE-2020-27252 Medtronic MyCareLink Smart 25000 is vulnerable to a race condition in the MCL Smart Patient Reader software update system, which allows unsigned firmware to be… medtronic · mycarelink_smart_model_25000_firmware 2020-12-14 hoch8.8 CVE-2020-25187 Medtronic MyCareLink Smart 25000 is vulnerable when an authenticated attacker runs a debug command, which can be sent to the patient reader and cause a heap ov… medtronic · mycarelink_smart_model_25000_firmware 2020-12-14 hoch8.0 CVE-2020-25183 Medtronic MyCareLink Smart 25000 contains an authentication protocol vulnerability where the method used to authenticate between the MCL Smart Patient Reader a… medtronic · mycarelink_smart_model_25000_firmware 2020-12-14 mittel5.8 CVE-2019-13543 Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energ… medtronic · valleylab_exchange_client, medtronic · valleylab_ft10_energy_platform_firmware, medtronic · valleylab_fx8_energy_platform_firmware 2019-11-08 hoch7.0 CVE-2019-13539 Medtronic Valleylab Exchange Client version 3.4 and below, Valleylab FT10 Energy Platform (VLFT10GEN) software version 4.0.0 and below, and Valleylab FX8 Energ… medtronic · valleylab_exchange_client, medtronic · valleylab_ft10_energy_platform_firmware, medtronic · valleylab_fx8_energy_platform_firmware 2019-11-08 mittel4.6 CVE-2019-13535 In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not … medtronic · valleylab_ft10_energy_platform_firmware, medtronic · valleylab_ls10_energy_platform_firmware 2019-11-08 mittel4.8 CVE-2019-13531 In Medtronic Valleylab FT10 Energy Platform (VLFT10GEN) version 2.1.0 and lower and version 2.0.3 and lower, and Valleylab LS10 Energy Platform (VLLS10GEN—not … medtronic · valleylab_ft10_energy_platform_firmware, medtronic · valleylab_ls10_energy_platform_firmware 2019-11-08 hoch7.1 CVE-2019-10964 Medtronic MiniMed Insulin Pumps are designed to communicate using a wireless RF with other devices, such as blood glucose meters, glucose sensor transmitters, … medtronic · minimed_508_firmware, medtronic · minimed_paradigm_511_firmware, medtronic · minimed_paradigm_512_firmware +9 2019-06-28 mittel6.5 CVE-2019-6540 The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer,… medtronic · mycarelink_monitor_24950_firmware, medtronic · mycarelink_monitor_24952_firmware, medtronic · carelink_monitor_2490c_firmware +9 2019-03-26 kritisch9.3 CVE-2019-6538 The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer,… medtronic · mycarelink_monitor_firmware, medtronic · carelink_monitor_firmware, medtronic · carelink_2090_firmware +9 2019-03-25 mittel4.6 CVE-2018-18984 Medtronic CareLink and Encore Programmers do not encrypt or do not sufficiently encrypt sensitive PII and PHI information while at rest . medtronic · carelink_2090_programmer_firmware, medtronic · carelink_9790_programmer_firmware, medtronic · 29901_encore_programmer_firmware 2018-12-14 mittel5.3 CVE-2018-14781 Medtronic MiniMed MMT devices when paired with a remote controller and having the “easy bolus” and “remote bolus” options enabled (non-default), are vulnerable… medtronicdiabetes · 508_minimed_insulin_pump_firmware, medtronicdiabetes · 522_paradigm_real-time_firmware, medtronicdiabetes · 722_paradigm_real-time_firmware +6 2018-08-13 mittel4.8 CVE-2018-10634 Communications between Medtronic MiniMed MMT pumps and wireless accessories are transmitted in cleartext. medtronic · minimed_paradigm_revel_mmt-523k_firmware, medtronic · minimed_paradigm_revel_mmt-723k_firmware, medtronic · minimed_paradigm_revel_mmt-723_firmware +6 2018-08-13 mittel4.4 CVE-2018-10626 Medtronic MyCareLink Patient Monitor’s update service does not sufficiently verify the authenticity of the data uploaded. medtronic · mycarelink_24952_patient_monitor_firmware, medtronic · mycarelink_24950_patient_monitor_firmware 2018-08-10 mittel5.2 CVE-2018-10622 Medtronic MyCareLink Patient Monitor uses per-product credentials that are stored in a recoverable format. medtronic · mycarelink_24952_patient_monitor_firmware, medtronic · mycarelink_24950_patient_monitor_firmware 2018-08-10 mittel6.3 CVE-2018-10631 The 8840 Clinician Programmer executes the application program from the 8870 Application Card. medtronic · n\'vision_8840_firmware, medtronic · n\'vision_8870_firmware 2018-07-13 mittel6.4 CVE-2018-8870 Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains a hard-coded operating system password. medtronic · 24950_mycarelink_monitor_firmware, medtronic · 24952_mycarelink_monitor_firmware 2018-07-03 mittel6.2 CVE-2018-8868 Medtronic 24950 MyCareLink Monitor and 24952 MyCareLink Monitor contains debug code meant to test the functionality of the monitor's communication interfaces, … medtronic · 24950_mycarelink_monitor_firmware, medtronic · 24952_mycarelink_monitor_firmware 2018-07-03

Benachrichtigungen erhalten

Abonniere neue Schwachstellen und Frühwarnungen der letzten sieben Tage. Wähle aus, was für deinen Stack wichtig ist, und kopiere die Adresse in einen beliebigen Feedreader. Sobald du einen Typ auswählst, erscheinen weitere Filter.

Format:
Feed öffnen

Frühwarnungen sind Sicherheitsmeldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, zu Meldungen mit noch ausstehender CVE und zu Berichten, die noch nicht geprüft wurden. Die Verlässlichkeit zeigt, wie gut ein Eintrag geprüft ist: hoch, mittel oder niedrig.

Über dieses Dashboard

Das Dashboard führt einen eigenen Index aus Sicherheitsmeldungen und aktualisiert ihn alle 30 Minuten. Es führt die nationale Schwachstellendatenbank, Paket-Advisories, Malware-Meldungen und den Katalog aktiv ausgenutzter Schwachstellen zu einem Eintrag pro Problem zusammen. Meldungen zur selben Lücke werden gebündelt, damit nichts doppelt erscheint.

Öffne einen Eintrag, um alle Details zu sehen: Beschreibung, CVSS-Vektor, betroffene Pakete und Versionen, behobene Versionen, Schwachstellenklasse, Ausnutzungswahrscheinlichkeit und Referenzen.

Quellen: die GitHub Advisory Database (geprüfte Advisories, Malware-Meldungen und ungeprüfte Berichte), die National Vulnerability Database, das CVE Program (cve.org) für ganz neue Einträge, die OpenSSF-Liste schädlicher Pakete, der CISA-Katalog Known Exploited Vulnerabilities und die Sperrliste von Microsoft für schädliche VS-Code-Erweiterungen. Jeder Eintrag nennt seine Quellen auf der Detailseite.

Dieses Produkt nutzt die NVD-API, wird von der NVD aber weder unterstützt noch zertifiziert.

So liest du die Zahlen

  • Bedrohungslage: eine Einstufung aus den drei Zahlen daneben: kritische Meldungen der letzten 24 Stunden, in dieser Woche neu bestätigte ausgenutzte Schwachstellen und Malware-Meldungen dieser Woche. Sie dient der schnellen Orientierung und ist keine offizielle Warnstufe.
  • Schweregrad: Werte ab 9.0 gelten als kritisch, 7.0 bis 8.9 als hoch, 4.0 bis 6.9 als mittel und 0.1 bis 3.9 als niedrig. Der Schweregrad beschreibt, wie schwer eine Lücke allgemein wiegt. Ob die Komponente in deiner Umgebung erreichbar ist, berücksichtigt er nicht.
  • Bekannt ausgenutzt: Die Lücke wurde bei echten Angriffen ausgenutzt. Diese Einträge solltest du zuerst patchen. Bei Einträgen mit Patch-Frist siehst du, wie viele Tage noch bleiben.
  • Frühwarnungen: Meldungen, die vor oder ganz ohne CVE-Nummer erscheinen, etwa zu Schadpaketen, geprüfte Advisories mit noch ausstehender CVE und Berichte, die noch nicht geprüft wurden.
  • Prioritätenliste: kritische und hohe Meldungen der letzten 7 Tage sowie alles, was neu ausgenutzt wird, sortiert nach Ausnutzung, Schweregrad und Score.

Häufige Fragen

Woher stammen die Daten?
Aus öffentlichen Schwachstellendatenbanken, Paket-Advisories und dem Katalog ausgenutzter Schwachstellen. NetSight sammelt sie alle 30 Minuten in einem eigenen Index und führt Doppelungen zusammen.
Wie prüfe ich, ob ich betroffen bin?
Suche nach deinem Produkt- oder Paketnamen, öffne den Eintrag und vergleiche deine installierte Version mit den betroffenen und den behobenen Versionen. Ein passender Produktname allein heißt noch nicht, dass deine Version betroffen ist.
Was bedeutet bekannt ausgenutzt?
Die Schwachstelle wurde bei echten Angriffen ausgenutzt. Solche Einträge tragen das Datum der Bestätigung und, falls vorhanden, eine Frist für das Einspielen des Patches.
Was ist eine Frühwarnung?
Eine Meldung, die vor oder ganz ohne CVE-Nummer erscheint, etwa zu einem Schadpaket oder ein geprüftes Advisory, dessen CVE noch aussteht. Du bekommst so einen Vorsprung, die Details können sich aber noch ändern.
Ist ein hoher Schweregrad immer dringender als ein niedriger?
Nein. Der Schweregrad misst die technische Auswirkung im Allgemeinen. Wie offen das betroffene System erreichbar ist, ob die Lücke bereits ausgenutzt wird und wie wahrscheinlich eine Ausnutzung ist, zählt genauso.
Kann ich neue Meldungen automatisch verfolgen?
Ja. Mit dem Feed-Baukasten weiter unten erstellst du einen RSS-, Atom- oder JSON-Feed, gefiltert nach Schweregrad, Technologie, Ökosystem oder Ausnutzungsstatus.